Ducted axial fans - IEC motor

industrial exhaust fans

Serie LUX-DUCT-M

DUCTED AXIAL FANS - IEC MOTOR

DUCT-M line is suitable when large air capacities with relatively low pressures are required in duct mounted applications.

For instance:
ventilation and conditioning in naval and mining applications, evaporative towers, heat exchangers, cooling of electric and refrigerating equipments, etc.

RANGE
This line consists of 6 sizes with impeller diameter from 310 up to 560 mm.

ADVANTAGES DUCT-M
line is characterised by the extreme sturdiness of construction, thanks to the flanges directly bended on the casing, and the thickness of the materials. The variety of versions and models allows the solution of most of the problems of ventilation. Impeller consists of a strong hub, in die-cast aluminum alloy for the fixing of the blades. Available in different materials suitable for heavy duties.

CONSTRUCTION

  • Casing in steel sheet protected with epoxy painting. Fixing flanges according to UNII SO 6580/EUROVENT 1-2 standards. 
  • Impeller with high efficiency airfoil blades in plastic material or in die-cast aluminum alloy. Hub in die-cast aluminum alloy. Balancing according to UNI ISO 1940. Variable pitch angle in still position. 
  • Asynchronous electric motor, protection IP 55, class F insulated, form B3, service S1 construction according to the IEC/EEC (UNEL-MEC) standard. 
  • Arrangement 4 (impeller directly coupled to motor shaft).
TECHNICAL SPECIFICATIONS
DUCT-M standard
  • Conveyed air: clean, not abrasive. 
  • Temperature of conveyed air: -20°C/+50°C. 
  • Voltage: three phase version (T) 400V-3Ph. Single phase version (M) 230V-1Ph. 
  • Frequency: 50Hz. 
  • Air flow from motor to impeller, position A (FMG).
VERSIONS
DUCT-Mm: medium lenght casing: motor/impeller assembly almost completely enclosed within the lenght of the casing.
DUCT-Ml: long casing. Impeller and motor are completely enclosed within the overall length of the casing.

ACCESSORIES
  • Inlet nozzle (IN). 
  • Flat protection grid (FPG-DU) 
  • Flexible connection (FC-DU). 
  • Counter flange (CF-DU).

ON REQUEST
  • Performances differing from standard 
  • Versions with impeller with in die-cast aluminum blades 
  • Versions with true reversible airflow (DUCT-REV). 
  • Smoke exhaust version (DUCT-Ht) 
  • Versions with casing in stainless steel, aluminum, or hot dip galvanised steel. 
  • Versions with air flow from impeller to motor, position B (FGM). 
  • Explosion proof versions (DUCT Atex)


Certifications

Accessories


Ducted axial fans - IEC motor

Noise level


Ducted axial fans - IEC motor

Graphics


Ducted axial fans - IEC motor

Performance

The picture shows the fan performances in the several diameters.

Ducted axial fans - IEC motor

Data table

The table shows all the data of the fan in the various diameters.

Ducted axial fans - IEC motor